50 Hz |
60 Hz
|
||
performance of air | max. 400-440 | 430-510 | m³/h |
pressure Pfa | max. 340-345 | 490-500 | Pa |
power out | 0,120 | 0,150 | kW |
voltage |
Δ/ Y 202-306 350-530
|
202-306 350-530 | V |
current | 0,55/0,32 | 0,51/0,29 | A |
speed | 2785 | 3310 | min/ ¯ ¹ |
frequency | 50 | 60 | Hz |
protection mode IP | 54 | 54 | |
noise level | 65 | 69 | dB (A) |
weight | ca. 4,0 | 4,0 | kg |
Fans with split-phase motors
The 1st product range of Karl Klein in 1965 - and still reliable today.
Application areas ·Extruders ·Heating boiler construction ·Switch cabinet construction |
Fan types ·ENG 1-2,8 B ·ENG 1-2,6 B ·ENG 1-1,6 B ·ENG 1-1,2 B ·ENG 1-0,8 ·ENG 1-0,65 |
Karl Klein 鼓風機
Karl Klein 一系列完整的產品,來自德國的工藝;從個別零組件之計算、設計、繪圖、
製造到組裝一氣呵成,針對各式各樣的運用,快速地回應以滿足客戶的需求。
|
分極式馬達 風量可達 150 m3/h 擠出機、加熱系統、開關櫃 |
|
外轉子 風量可達 500 m3/h 結構緊湊、省空間 儀器、通風系統、緊湊型單元 |
|
低壓型 (後彎曲葉片) 風量可達7,350 m3/h 熱風溫度可達 350℃ 除塵、鐵路、飲水機、表面處理、 磨機、乾燥、烤箱、包裝 |
|
低壓型 (連軸傳動型) 風量可達72,000 m3/h 熱風溫度可達600℃ 除塵、鐵路、飲水機、 表面處理、磨機、乾燥、 烤箱、包裝 |
|
低壓型 (前彎曲葉片,可雙扇葉) 風量可達 7,000 m3/h 熱風溫度可達 400℃ ATEX (防爆) zone 1, 2, 22 (介質溫度 -20 ~ +60℃) |
|
中壓型 (變頻、正/反轉) 熱風溫度可達 300℃ ATEX (防爆) zone 1,2,21,22 (介質溫度 -20 ~ +60℃) |
|
中壓型 風量可達 36,000 m3/h 除塵、鐵路、飲水機、表面處理、 研磨、乾燥、烤箱、包裝、電站、 食品 |
|
高壓型 (速度可達130Hz) 熱風溫度可達 300℃ 防爆(介質溫度 -20 ~ +60℃) |
|
鍋爐型 (直列式葉片) 耐溫可達 300℃ 用於運輸灰塵或煤煙顆粒 |
|
移動型 (伸縮手柄、兩輪) 加油站、庫存、船舶集裝、充填站、 吸管、鐵路、木質顆粒車(無防爆) |
|
熱風型 (熱風溫度可達 600℃) 工業烤箱、熱處理爐、對流器、 輻射供暖、焚化爐、熱處理廠、 貝克烤箱、循環空氣操作 |
|
氣密型 (焊接密封) 螺絲及螺紋密封 防滲報告 附加密封法蘭之馬達洩漏規格 |
|
不鏽鋼型 熱風溫度可達 600℃ 焊接經過玻璃粒噴砂處理 防爆(介質溫度在-20~+60°C) |
|
鑄鐵型 介質溫度可達 400℃ 基座可旋轉達 45°、變頻驅動 防爆(介質溫度在-20~+60°C) |
|
輸送帶 (直列式葉片) 鑄鐵外殼、不鏽鋼直列式葉片 輸送砂礫粉塵、刨花和輕質物料 |
|
隔音型 外殼護套可減少結構聲 彈性材料完全包覆或使用隔音罩 可做溫度隔離 |
|
大流量 風量可達 650,000 m3/h 重型工業設計、折疊式葉輪、 外殼套用於隔音、分半箱 防爆(介質溫度在-20~+60°C) |
|
插入型 介質溫度可達 650℃ 後彎曲扇葉、皮帶或直接驅動 防爆(介質溫度在-20~+60°C) |
|
防爆型 (氣體防爆 zone 1, 2) 溫度等級 T3, T4 - T6 沼氣廠、電加熱、環境、庫存、 排氣、潔淨室、加油站、磨機、 船隻 |
|
防爆型 (粉塵防爆 zone 21, 22) 溫度等級 T 125℃、IP65 過濾廠、灌裝、銑削 |
External rotor fans
For the most varied application areas - compact and space-saving
Application areas ·Apparatus engineering ·Ventilation systems ·Compact units |
Fans ·ENG 5-10 A ·ENG 4-6 A ·ENG 3-4 A |
Low-pressure fans with drum impellers - to 7,000 m3/h, 11.0 kW
Gap-free production program in series production
Standard ·Compact design ·Impellers with a high volume flow and small diameter, available with a wheel Ø of up to 315 mm or 11.0 kW ·Case made from steel sheet, painted black ·Clockwise or anti-clockwise rotation ·Frequency adjustable |
Extensive accessories ·Available as a dual fan ·Up to 1.0 kW in multi-range voltage 50/60 Hz ·V2A, from 0.55 kW V4A ·For hot air to 400°C in continuous operation ·ATEX zone 1 and 2 or Zone 22 (for media temperature of between -20°C and +60°C) ·Rail-suitable design ·With hydraulic drive ·Water-cooled drive |
Low-pressure fans with backward curved blades
Standard ·2- or 4-pole ·Highly efficient impellers ·Case made from steel sheet ·Clockwise or anti-clockwise rotation ·Frequency adjustable |
Optional ·Coupling ·Extensive accessories ·Stainless steel (V2A, V4A) ·For hot air to 600°C in continuous operation ·ATEX zone 1, 2, 21, or 22 (for media temperature of between -20°C and +60°C) |
Medium-pressure fans
Standard ·Fan case made from painted steel sheet ·Impellers made from aluminium (for ATEX: Steel impellers) ·With backward or forward curved blades ·Frequency adjustable |
Optional ·Stainless steel (V2A, V4A) ·For hot air to 400°C in continuous operation ·ATEX zone 1, 2, 21, or 22 (for media temperature of between -20°C and +60°C) |
High-pressure fans
Special features ·Speeds of up to 130 Hz ·Variable frequency drive built on or as switching cabinet version ·Impellers made from aluminium (for ATEX: Steel) |
Optional ·Stainless steel (V2A, V4A) ·Hot air to 300°C (more or less than this in individual cases) ·ATEX (VFD in switching cabinet, for media temperature of between -20°C and +60°C) |
Boiler fans
Special features ·Motor can be supplied with Hall sensor as ·rotational speed monitor |
Specifications ·Seal-welded case ·Impellers with straight blades, suitable for dust and soot particles ·Temperature barrier to 350°C |
Mobile fans
Application areas ·Fuel station service ·Storage systems ·Ship containers ·Rail containers ·Filling stations ·Long suction sections ·Wooden pellet delivery vehicles |
Specifications ·Frame with 2 wheels in stable industrial design ·Telescopic handles ·Can be carried with a carry handle
Special features ·Type examination certificate as per DIN EN 14986 and DIN EN 13463 ·3 x 400 V, 50 Hz drives, from 0.12 to 1.5 kW ·Suitable for use in zones 1, 2, and 22 |
Hot air fans - up to 600°C in continuous operation
Application areas ·Industrial oven construction ·Baker's oven construction ·Radiant heating systems ·Convectors ·Heat treatment furnaces ·Incinerators ·Recirculating air operation ·Heat treatment plants |
Special features Can be supplied with sealed temperature barrier Plug fan as of impeller diameter of 710 mm to 600°C continuous operation |
ATEX zone 1 and 2 fans
Application areas ·Biogas plants ·Environmental technology ·Storage technology ·Shipbuilding ·Electrical heating systems ·Suction systems ·Clean room technology ·Filling systems |
Special features ·Gas Ex-zones 1 and 2 ·Explosion groups IIA, IIB, and IIC as per DIN EN 14986 ·Temperature class T3, temperature class T4 - T6 available on request ·Variable frequency drive operation ·"Non-electrical equipment" as per DIN EN 13463 Parts 1 and 5 ·Documentation for drive (electrical part) and fan (non-electrical part) |
ATEX zone 21 and 22 fans
Application areas ·Filter technology ·Filling systems ·Large-scale mills |
Specifications ·Dust Ex-zones 21 and 22 ·Explosion groups IIIA, IIIB, and IIIC as per DIN EN 14986 ·Temperature class T 125°C ·Variable frequency drive operation ·"Non-electrical equipment" as per DIN EN 13463 Parts 1 and 5 ·Documentation for drive (electrical part) and fan (non-electrical part) ·Ex-protection for dust-containing media in or around fan |
Gas-tight fans
Special features ·Seal-welded fan case ·Sealed screwed-on parts, including screws/threads ·Impermeability report ·Specification of motor leakage rate with additional sealing flange |
Stainless steel fans
Special features ·Case, impeller, motor shaft, screws in stainless steel ·Material V2A (AISI 314) or V4A (AISI 316) ·Accessory parts in V2A ·Welded assemblies are glass-bead-blasted |
Optional ·For hot air to 600°C in continuous operation ·ATEX (for media temperature of between -20°C and +60°C) |
Cast fans
Standard ·Case made from cast iron, including base ·Base can be rotated up to 45° ·Suction-side flange connection with threaded holes ·Pressure-side flange connection with through-holes ·Felt seal on shaft passage ·Suction-side silicone seal on case cover ·Motor with PTC thermistor |
Optional ·50 or 60 Hz operation ·Pole-changeable ·ATEX (for media temperature of between -20°C and +60°C) ·Suitable for variable frequency drive operation ·Media temperature of up to 400°C in continuous operation |
Kamptmann fan wheels
Special features ·Closed impellers ·Open impellers for the conveyance of materials, e.g. films or textile residue ·Forward curved, riveted or welded drum impellers ·Inlet nozzles ·Materials: ·Aluminium ·Painted or zinc-plated sheet steel ·Stainless steel AISI 314 or 316, N-A-XTRA® ·Impeller diameter of max. 1,500 mm |
Transport fans (cast iron)
Special features ·Case made from cast iron, sealed ·Impeller made from steel with straight blades ·Stainless steel or N-A-XTRA® ·Suitable for the conveyance of coarse dusts, chips, and light bulk goods |
Sound protection measures
Special features ·Case sheathing for reduction in structure-borne sound ·Complete enclosures. Flexible, as case insulation or with sound protection canopy. ·For the isolation of thermal processes |
Large-volume radial fans - from our plant in Eisenberg/Thüringen
Special features ·Volume flows of up to 650,000 m³/h ·Pressure differences of up to 25.0 kPa ·Belt, coupling, or direct drives ·Heavy-duty industrial design ·Painting as per customer's requirements ·Media temperatures to max. 650°C ·Case sheath for sound insulation ·Split case halves ·Fold-out impeller ·ATEX designs (for media temperature of between -20°C and +60°C) |
Radial plug fans
Special features ·Our own high-performance impellers with backward curved blades ·Impeller diameter of max. 2,500 mm ·Media temperatures of max. 650°C, with insulation housing if required ·Application-optimised material selection, e.g. sheet steel, stainless steel, N-A-XTRA® ·Mounting plates as per the customer's requirements ·Belt or direct drives ·ATEX designs (for media temperature of between -20°C and +60°C) |
原廠網址: https://www.karl-klein.de/en/